Technical Specifications
- Operating Voltage: DC 12V
- Standby Current: ≤ 35mA
- Operating Current: ≤100mA
- Operating Temperature: -20℃~60℃
- Operating Humidity: 0%~95%
- Electric lock signal relay contact current:≤1A
- Alarm signal MOS tube output current: ≤1A
- Unlocking time: 0~300s adjustable
3. Wiring
|
Colour |
Function |
Description |
|
Green |
D0 |
WG output D0 |
|
White |
D1 |
WG output D1 |
|
Yellow |
OPEN |
Exit button one end(the other end connected GND) |
|
Red |
12V+ |
12V + DC Regulated Power Input |
|
Black |
GND |
12V-DC Regulated Power Input |
|
Blue |
NO |
Relay normally-on end(Connect positive electric lock “-“) |
|
Purple |
COM |
Relay Public end, connect GND |
|
Orange |
NC |
Relay Closed end(connect negative electric lock”-“) |
4. Diagram
Common Power Supply

Note: The door contact and alarm function are optional
Special Power Supply

Note: The door contact and alarm function are optional
Reader Mode